Specifications:
Applicable Amplifier Units ZX2-LDA11/ZX2-LDA41
Current consumption 12 mA max. (supplied from the Smart Sensor Amplifier Unit)
Ambient temperature Operating: 0 to +50 °C, storage: -15 to +70 °C (with no icing or condensation)
Ambient humidity Operating and storage: 35 to 85% (with no condensation)
Connection method Connector
Dielectric strength 1,000VAC, 50/60 Hz for 1minute
Vibration resistance (destruction) 10 to 150Hz, 0.7-mm double amplitude, 80minutes, each in X, Y, and Z directions
Shock resistance (destruction) 300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)
Materials Case: ABS, Display: Acrylic resin
Weight (packed state) Approx. 50g (Calculating Unit only: Approx. 15g)
Accessories Instruction sheet